Version française
Biobank Data Base
Rapid Tissue Freezing
Imaging
Introduction to Tissue Arrays
Ready-to-use Tissue Arrays
Design of TMAs
Automatisation kit
for Beecher TMA1
Accessories
Tissue Arrays Sections
Analysis of TMAs
TISALYS® Data Base
Publications & Links
   
Tissue Array
Analysis Workstation
Spot Browser® 3
Distributors wanted
 Automated Tissue Array Analysis Workstation
 SPOT BROWSER® V2e

SPOT BROWSER 2 ACCELERATES DISCOVERY OF PROGNOSIS MARKERS IN COLON CANCER. More

The new generation of Tissue Array Analyzer for even faster and simpler analysis
Tissue Array are now becoming a really new tool to study large numbers of tissues, whether you are looking at morphology, immunohistochemistry or in situ hybridization.
Analysis of these numerous tissues under microscope is a tedious and error-generating task. Moreover, data processing becomes rather complex due to the large volume of data to be analysed.
For many months now, SPOT BROWSER® has been bringing to the pathologists an elegant, simple and efficient solution to these issues and overcomes these limitations.
SPOT BROWSER® is a dedicated image analysis workstation integrated on microscope, visualizing and capturing images through colour CCD camera and using a motorised stage. It allows rapid scanning of the tissue array to build the road map, assignment of defined coordinates to tissue spots to guarantee a total tracking and provides a user's interface for pathologist's visual inspection conclusions input and short keys for fast and easy tissue array browsing. Collected data and images
(Click to enlarge)
can be exported readily to Excel for further data processing.
ALPHELYS introduces now its SPOT BROWSER® V2, its new generation of automated analyzer for tissue arrays. This new realease accelerates tissue array analysis and brings new functionalities like objects detection and signal quantitation. SPOT BROWSER® V2 facilite la consultation post-analyse des données collectées image et information.
Simplified experiment configuration
SPOT BROWSER® V2 simplifies tissue array analysis parameters configuration.
SPOT BROWER® V2 allows you to analyse your tissue arrays either through visual inspection on the oculars or on the high resolution screen or through automated detection of specific events like nuclei counting, signal quantitation, surface determination, morphometry or both methods simultaneously.
Identify your slide, your experiment and the operator.
Create data input fields for visual inspection (not limited) with a choice of free or list mode entry i.e. grading +/++/+++/-.
Create events to be detected automatically and run a simple rtouine to learn the software what to detect.
(click one of the picture to enlarge it)
top of page
Flexible grid system for coordinates assignment
SPOT BROWSER® V2 assigns precise coordinates on each tissue spot (i.e. block 1, spot A1...) eliminating any risk of errors while browsing your tissue array.
The flexible grid system of SPOT BROWSER® V2 easily handles any format of tissue arrays, with or without sub-grids, of different formats, even when tissue arrays are heavily deformed.
Each grid and sub-grid can be named and saved as a template for use in the next analysis of the same format.
SPOT BROWSER® V2 records precisely the micrometered position of each spot in the tissue array at user specified magnification. You may then easily process an analysis in multiple steps over time, as many as you want.
SPOT BROWSER® V2 creates a road map of the tissue array at low magnification. The road map is dynamically linked to the video live image
(Click to enlarge)
to allow rapid access to any spot of tissue thourgh a simple mouse click into the road map without getting lost, even when at high magnification.
top of page
User defined interface for tissue array visual inspection conclusions imput
As in the routine job, most of the analysis done in morphology or in IHC can be only performed reliably by visual inspection. SPOT BROWSER® V2 provides a fully user defined interface to allow on line visual inspection conclusions entry into dedicated fields.
This user's interface has been optimised in collaboration with the pathology laboratory of Paoli CALMETTES Institute of Cancer Research (Marseille, France), Dr Jocelyne JACQUEMIER, well experimented pathologits on tissue arrays analysis.
The data input are extremely fast, with automated data saving, spot image capture at observationmagnification and next spot browsing. SPOT BROWSER® V2 reduces workload and makes tissue array data easily processable.
(Click to enlarge)
top of page
Automated detection of events
SPOT BROWSER® V2 allows simultaneous visual inspection data input and events automated detection with automated results saving into dedicated tables.
Operator can easily choose between those two options of analysis through short keys.
The SPOT BROWSER® Technology allows detection of events on a non-captured images for faster analysis procedure.
(Click to enlarge)
top of page
Analysis results and images archiving
Results of tissue array analysis and tissue spots images are archived into tables that ensure the link with tissue spots ID for a guaranteed tracking.
The data base can be readily exported to Excel sheet with export routine or to .csv and .txt files.
When using automated detection of morphometry tools, all drawings generated are automatically saved together with the image of the spot and their relative position preserved at the specified magnification for later analysis control. Images can be improved and annotated.
(click one of the picture to enlarge it)
top of page
Analysis results and spots images consultation
Tissue array analysis results and spots images can be reviewed at any time after analysis has occured and without the slide from the local or distant computer.
Reviewing a tissue array analysis with the related slide under the microscope allows rapid relocation of the spots through dynamic link between tables and spot position to visualise again the spot together with the results obtained for possible control and modification.
(Click to enlarge)
top of page
Audit trail
An audit trail report tracks all analysis data and captured images and can be print any time without particular configuration.
(Click to enlarge)
The integrated SPOT BROWSER® V2 workstation
SPOT BROWSER® V2 is an integrated and optimised workstation including:
- An upright microscope with bright and/or fluorescence objectives set;
- A motorized 2 axis stage, 1 slide position with remote controller and joystick;
- A high resolution tri CCD video colour camera une caméra couleur triCCD de haute résolution;
- A DELL computer configured for high performances imaging including a specific real time non destructive overlay managing frame grabber and a 21'' flat screen for a permium comfort of analysis;
- Spot Browser® V2 licence.
(Click to enlarge)
   
The workstation may be used for other more regular iamging applications.
We can provide you with customized configuration to integrate components you may have already available at your lab. Don't hesitate to contact us !

PUBLICATIONS

• Pagès F and al. Effector memory T cells, early metastasis, and survival in colorectal cancer. N Engl J Med. 2005 Dec 22;353(25):2640-1. Pubmed ID : 16371631
• Galon and al.,Type, Density, and Location of Immune, Cells Within Human Colorectal Tumors, Predict Clinical Outcome, SCIENCE, 2006 Sep 29, Vol 313, 1960.

To order

Spot Browser® V2
Catalog # 00-SBR-02
 
I wish a quotation.
I wish more information.
top of page
ALPHELYS, Ferme des Ebisoires, Impasse Paul Langevin, 78370 Plaisir - France
Tel +33 (0)1 30 07 52 95 - Fax +33 (0)1 30 07 51 56 - Email info@alphelys.com